  • BJ-918B1 Scrap Cable Wire Stripping Machine

    BJ-918B1 Scrap Cable Wire Stripping Machine

    * Diameter from 1.5mm to 98mm
    * This cable stripping machine is the best choice for small recycler of cable recycling.
    * Cut the waste cable into 1-2 meters.
    * Put the waste cable into the hole of cable stripper.
    * Cable stripped will go out from another side.
  • BJ-918B Scrap Cable Wire Stripping Machine

    BJ-918B Scrap Cable Wire Stripping Machine

    * Diameter from 1.5mm to 98mm
    * This cable stripping machine is the best choice for small recycler of cable recycling.
    * Cut the waste cable into 1-2 meters.
    * Put the waste cable into the hole of cable stripper.
    * Cable stripped will go out from another side.
  • BJ-920 Manual Scrap Wire Stripper

    BJ-920 Manual Scrap Wire Stripper

    Appropriate Wire Size: 1-20mm
    Daily Output: 50 – 100Kg
    Measurement: 300×220×350mm
    Net Weight: 3.0Kg
  • BJ-930 Scrap Cable Wire Stripping Machine

    BJ-930 Scrap Cable Wire Stripping Machine

    *Available wire diameter range:1.5mm ~ 20mm
    *Motor Voltage: AC220V, 50/60HZ
    *Daily Output: 50 – 300Kg
    *Dimension of machine: 86cm*40cm*41cm
    *Net Weight: 32Kg
    *Package: Wooden case
  • BJ-940 Scrap Copper Wire Stripper Machine

    BJ-940 Scrap Copper Wire Stripper Machine

    *Available wire diameter range:1.5mm ~ 38mm
    *Motor Voltage: AC220V, 50/60HZ
    *Daily Output: 200-500Kg
    *Dimension of machine: 63cm*37cm*48cm
    *Net Weight: 77Kg
    *Package: Wooden case
  • BJ-002 Automatic Wire Feeder Machine

    BJ-002 Automatic Wire Feeder Machine

    * Speed: 3000mm:sec(Max.)
    * Power supply: AC 110V/220V, 50/60Hz
    * Adjust speed by manual
    * Test length by auto-induction.
    * Suitable for stripping machine, automatic stripping, crimping machine.
    * Built-in computer automatically controls speed and number of rotation in accordance with speed of feeding.
  • FD-900 Coil Winding Machine

    FD-900 Coil Winding Machine

    * Max. wire guiding width: 110mm
    * Wire guiding precision: 0.001mm
    * Max. coil outer diameter: 200mm
    * Suitable wire gauge: 0.05~1mm
    * Winding speed: 6000rpm(adjustable)
  • FD-920 Coil Winding Machine

    FD-920 Coil Winding Machine

    * Suitable wire gauge: 0.05-2mm
    * Winding speed: 1500rpm
    * Storable winding: 999
    * Counting range: 0-99999 turns
    * Counting precision: 0.1 turn
  • FD-980 Coil Winding Machine

    FD-980 Coil Winding Machine

    * Spool quantity: 1
    * Max. wire guiding width: 180mm
    * Wire guiding precision: 0.001mm
    * Max. coil outer diameter: 300mm
    * Suitable wire gauge: 0.05-3mm

Common failures and methods of wire stripping machine.


1. The length of front wire is different.
A. If the clearance is too large for the left transmission line, adjust the left clearance.
B. The straightener is pressed too tightly. Adjust the straightener adjustment knob.
C. The catheter is not aimed at the center of the knife, and it will adjust the catheter to the center of the blade.

2. The length of the back wire is different.
There is too much clearance for the right transmission line. Adjust the right clearance adjustment disc to the right clearance.

3. The total length is inconsistent with the actual setting parameters.
A. It is longer than the set length, which is due to the systematic error in the mechanical transmission, you need to reduce the value of "L" in the mode.
B. It is shorter than the set length. Because the gap and pressure adjustment between the two wheels of the left transmission line is not suitable, and the value of "L" should be increased in the mode.
C. The length is not consistent because of the failure of the straightener to send the line. It is necessary to adjust the pressure of the right transmission line to the suitable clearance, keep the straightener sent smoothly.

4. The front-end incision is inclined.
It is due to the improper positioning of the catheter. Align the tube with the center of the knife edge.

5. The line head is stripped out of normal while the line end is normal. Some of the incisions are inclined, some of the line cores are cut.
Because the position of the tube is too close to the blade. Adjust the position of the tube, so that the distance between the front end of the tube and the blade is greater than the distance from the line tail (A).

6. The front or the back is cut off in the same bundle line.
Because the edge of the blade is too blocked by too much wire skin and clean it with a brush.

7. The insulation skin is overlaid.
Because there is the excessive pressure on the left and right transmission line. Reduce the left and right pressure wheel.

8. Stripping or stripping in the middle, the length L is qualified, but the size of A.B does not meet the requirements of setting.
A. The wire quality is not qualified, the insulation layer is too loose to the core wire, and the qualified conductor can be replaced.
B. The insulation layer is too soft which is pushed to deformation in machining molting process. The prototype cannot be recovered by external. It is the processing method itself that has the inherent defect. Thus reduce the requirements on the accuracy of length.
  • TEL:+86-512-57169166